WATER METER IRRIFONT-ITRON MODEL

<< Volver a la galería

WATER METER IRRIFONT-ITRON MODEL

Description

The IRRIFONT is a water meter suitable for irrigation applications. It uses Woltman technology witth horizontal propeller, is approved as a class B to operate in any position, keeping this clase.The mechanism has a different approval to the counter itself, which allows the exchange of a mechanism without re-calibration, facilitating maintenance.
The IRRIFONT counter is pre-equipped to communicate through a pulse generator, the Cyble system, allowing the installation of RF modules type or a pulse output reliably.
MID class B type Woltman pre-equiped to comunication.

Caliber

mm

50

65

80

100/125

150

200

250

300

  • Approval values MID

Constant flow Q3

m3/h

40

63

63

160

400

630

1000

1600

Overload flow Q4

m3/h

50

79

79

200

500

787,5

1250

2000

Transition flow Q2

m3/h

1,02

1,60

1,60

2,56

4

25,20

40

32

Minimum flow Q1

m3/h

0,63

1

1

1,60

2,50

15,75

25

20

Maximum admissible pressure

bar

20

Maximum admissible temperature

ºC

30

MID approval number

 

LNE-23696-2

 

 

  • Metrological characteristics

Boot flow

m3/h

0,19

0,22

0,30

0,38

0,40

1,60

3

10

Maximum flow

m3/h

50

79

79

200

500

788

1250

2000

Exceptional flow few minutes

m3/h

90

200

250

300

700

1000

1500

2500

Error ±2% desde

m3/h

0,4

1

1,2

1,5

1,6

3,5

5

15

Error ±5% desde

m3/h

0,35

0,5

0,75

0,9

1

2,5

3,5

12

Máx. temperature (short time)

ºC

50

Pressure drop Qmax

bar

0,12

0,12

0,15

0,15

0,14

0,45

0,15

0,15

Maximum reading

m3

999 999.99

9 999 999.9

Sensor Cyble pulse

l

10

100



NOTA: We also have counters to manage the drinking water Itron - model Woltex
Cyble communication modules have been designed to meet the needs of billing water meter through remote reading.

The Cyble sensor is a pulse generator that allows several possibilities of remote reading applications for residential, commercial or industrial use.


Allows:

LF outputs (Low frequency):
  • Remote readinga
  • Cumulative consumption

HF outputs (High frequency):
  • Flow analysis (data logger)
  • Conversion frequency
  • Automatic control

The Cyble Sensor complies with standard E.M.C. for protection against electromagnetic interferences.